Energy Management Modular Smart Power Quality Transducer Type PQT-H

February 19, 2018 | Author: Marjory Hodges | Category: N/A
Share Embed Donate


Short Description

1 Energy Management Modular Smart Power Quality Transducer Type PQT-H Up to optional digital inputs (sync function, remo...

Description

Energy Management Modular Smart Power Quality Transducer Type PQT-H

• Up to 12 optional digital inputs (sync function, remote digital input control) • Up to 16 optional digital outputs (pulse, alarm, remote control) • 16 freely configurable alarms with OR/AND logic linkable with up to 4 relay outputs and up to 16 open collector outputs • Up to 8 optional analogue outputs (+20mA, +10VDC, +/- 5mA) • Universal power supply: 18-60VAC/VDC, 90-260 VAC/VDC • Protection degree: IP 20

• Class 0.2 (current/voltage) • ARM® powered • Measurement of single phase and system instantaneous variables: W, var, VA, PF, VLL, VLN, AL, An, Hz, THD, ASY VLL, ASY VLN (for all measurements max, min, dmd/AVG and max dmd/AVG values) • Measured energies (imported/exported): kWh and kvarh • Current and voltage inputs with autoranging capability • Instantaneous variable in IEEE-754 floating point format • Total and partial energies unsigned 64bit data format • Energy measurements according to ANSI C12.20, CA 0.5, EN62053-22 CL 0.5S and ANSI C12.1, EN62053-23 CL 2 • 4 total 3-phase, 48 partial 3-phase and 12 total single phase independent energy meters to be used as single, dual, multi-time tariff management • Harmonic distortion analysis (FFT) up to the 63rd harmonic with numeric indication (current and voltage) • Harmonics source detection • Data stamping of up to 10,000 events: alarm, min, max, digital input status, digital output status as remote control, resets • 3 independent communication ports: optional RS 422/485 serial port, optional RS232 + real time clock function (with back-up), optional Ethernet port • MODBUS RTU and TCP, JBUS protocol, iFIX SCADA compatibility • Real time clock function (without back-up)

Product Description

How to order

PQT-H see next page

How to order

PqtHSoft

3-phase utility grade power quality transducer. Particularly recommended for the measurement of the main electrical variables. Housing for DIN rail mounting. RS485/RS232 commu-

nication ports, Ethernet port, pulse and alarm outputs available on request. Parameters programming and data reading by means of PqtHSoft.

Parameters programming and data reading by means of PqtHSoft.

Modules Combination Description PQT-H base Power supply (18-60VAC/DC) Power supply (90-260VAC/DC) Measuring input (AV5: 400/690VL-L) Measuring input (AV6: 120/208VL-L) RS485 port (9 600 bps) RS485 port (115,200 bps) Ethernet/Internet port Analogue output (20mA DC) Analogue output (10V DC) Analogue output (+/-5mA DC) Relay output Relay output Open collector output Open collector output Open collector output Digital inputs Digital inputs + Aux RS232 port + RTC (9 600 bps)

Part N. AD2020 AP1021 AP1020 AQ2030 AQ2031 AR1034 AR2040 AR1061 AO2050 AO2051 AO2052 AO1058 AO1035 AO1059 AO1036 AO1037 AQ1038 AQ1042 AR1039

Specifications are subject to change without notice

Slot A

Slot B

Slot C

Slot D

2-out 2-out 1-out 2-out 1-out 2-out 4-out 3-in 3-in

2-out 2-out 1-out 2-out 1-out 2-out 4-out 3-in 3-in

Slot E

1-port 1-port 1-port 2-out 2-out 2-out 1-out

2-out 2-out 2-out 1-out

1-out 2-out 4-out 3-in 3-in

1-out 2-out 4-out 3-in 3-in

PQT-HDS171006

1-port

1

PQT-H

How to order PQT-H Ordering key (fully assembled instrument):

Description

PQT-H

Ch Part No.

Legend

AD2020

PQT-H

AV53 H XX XX XX XX XX

Model

PQT-H base

Range code + system (measuring inputs) 400/690VL-L 1/5A (10A) 120/208VL-L 1/5A (10A)

AQ2030 AQ2031

AV5.3 AV6.3

AP1021 AP1020

L H XX E2 D1 D2 O4 O2 O1 R1 B1 W1 B2

3 3 4 2 1 1 2 2 2 1 1

AQ1038 AQ1042 AO1037 AO1036 AO1059 AO1058 AO2050 AO2051 AO2052 AR1034 AR2040

None Digital inputs Digital inputs + aux Open collector output Open collector output Open collector output Relay output Relay output Analogue output 10VDC Analogue output +/-5mA

3 3 4 2 1 1 2 2 2

AQ1038 AQ1042 AO1037 AO1036 AO1059 AO1058 AO1035 AO2051 AO2052

None Digital inputs Digital inputs + aux Open collector output Open collector output Open collector output Relay output Relay output Analogue output 10VDC Analogue output +/-5mA

3 3 4 2 1 1 2 2 2

AQ1038 AQ1042 AO1037 AO1036 AO1059 AO1058 AO1035 AO2051 AO2052

1

AR1039

Utility grade RS232 + RTC (utility grade) Revenue approval. An “instrument setting” form must be properly filled up by the user. RS232+RTC + “XU” option

1

AR1039

B

XX D1 D2 O4 O2 O1 R1 B1 W1 B2 S1 S2

C

XX D1 D2 O4 O2 O1 R1 R2 W1 xx

D

XX D1 D2 O4 O2 O1 R1 R2 W1 B2

SLOT

None Digital inputs Digital inputs + aux Open collector output Open collector output Open collector output Relay output Analogue output 20mADC Analogue output 10VDC Analogue output +/-5mA RS485 9600bps RS485 115200bps

A

SLOT

AR1061 AQ1038 AQ1042 AO1037 AO1036 AO1059 AO1058 AO2050 AO2051 AO2052

SLOT

1 3 3 4 2 1 1 2 2 2

SLOT

None Ethernet/Internet port Digital inputs Digital inputs + aux Open collector output Open collector output Open collector output Relay output Analogue output 20mADC Analogue output 10VDC Analogue output +/-5mA

OPTIONS

18-60VAC/DC power supply 90-260VAC/DC power supply

SLOT

Power supply

E

XX SX XU

Example of which modules to order for: PQT-H AV53 H B1 S1 R2 O2 SX

Bill of material PQT-H AV53 measuring inputs (400/690VL-L) 90-260VAC/DC power supply Analogue output 20mA (2 channels) RS485 serial port 9600 bps Relay output (2 channels) Open collector (2 channels) RS232 port+RTC

A

B

C

Options (E)

SU

Power Supply

2

Specifications are subject to change without notice

Ordering No. AD2020 AQ2030 AP1020 AO2050 AR1034 AO1035 AO1036 AR1039

D

Measuring Input (Range + system) PQT-HDS171006

PQT-H

Input specifications Number of analogue inputs Current Voltage Digital inputs (on request) AQ1038 Purpose

Contact measuring current AQ1042 Purpose

Excitation output Contact measuring current Common characteristics Close contact resistance Open contact resistance Insulation Accuracy (display, RS232, RS485) Current (AL1, AL2, AL3) (@20°C ±5°C, R.H. ≤75%) Current (An) Voltage (@20°C±5°C,R.H.≤75%) range AV5:

range AV6:

Frequency Active power and apparent power (@ 20°C ± 5°C, R.H. ≤ 75%)

Reactive power (@ 20°C ± 5°C, R.H. ≤ 75%)

1 (1-phase; system code: 3) 3 (3-phase; system code: 3) 1 (1-phase; system code: 3) 4 (3-phase; system code: 3) Up to 12 No. of inputs: 3 (voltage-free) “dmd” measurements synchronisation. Tariff selection: energy. Contact status reading. Clock synchronisation.